This area contains Sceptre 5.0 amendment notices. To use any of these amendments, the relevant file should be downloaded to a local disk, uploaded to VME, the AMENDMODULE parameters merged into the appropriate patch file and the file executed as described in the comments at the start of the patch file.
The amendments contained in this file area have all had their local tags, indicated by a £ (pound sign) replaced with a # (hash), so that the files will only contain ASCII (7-bit) characters. The transfer method used to move these files onto your VME system should be configured so that hash (#) characters in the ASCII source files are translated to pound (£) characters in the EBCDIC destination.
Note: The majority of the files contain only text and selecting them will cause your browser to show the file contents rather than saving them to your local drive. If you wish to save the contents of the file, you can either:
If you have any problems or questions regarding files on this web site, please send an email to support@ultracomp.co.uk.
| asummary | Summary descriptions of latest amendments. All amendments now contain # (hash) in place of £ (pound sign). |
| s500amn.exe | Self extracting archive of all the available amendments. All amendments now contain # (hash) in place of £ (pound sign). |
| 634 | RE: Ultracomp VME Products and the ICL Year 2000 Enabling Kit Ref: ICL PC-Paris SKE 93697 Describes a problem caused by the ICL Year 2000 enabling kit and proivides a solution. |
| 633 | This amendment causes the Sceptre IDMS snapshot to use the new module produced by Sceptre amendment 631. |
| 632 | This amendment causes the Sceptre IDMS snapshot to use the new module produced by Sceptre amendment 631. |
| 631/1 | This notice introduces a new Sceptre module which will be used by the
Sceptre IDMS monitor and Snapshot. This new module enabled Sceptre IDMSX 610
services to be monitored. The new module is created by the SCL procedure ICL8_UCSP_631, which should be placed in the Sceptre ICLRSISOURCE library and then executed using EXSCL. |
| 630 | The Sceptre snapshot "VM Usage" screen shows the application
servername of a VM running Open-TP as part of the username, this causes the
jobname to be truncated.
This amendment removes the application servername from the username. |
| 628 | This amendment and its accompanying SCL procedure introduce a delay into the Sceptre TPMS monitor whenever the monitor detects that the TPMS service CVM has been loaded. This is to give the CVM a chance to load and initialise the service tables before the monitor attaches itself to them. |
| 627 | There is a problem with the Sceptre UCS_TELL command that can cause it to
fail with a result code of 31501 or -31753 along with the following error
message: FAILURE CALLING VME INTERFACE FOR ...TELL COMMAND This amendment corrects this problem. |
| 625 | UCS_TREND_UPDATE will fail if an input file has a generation gap that is greater than 100 generations. This amendment increases the maximum permitted gap to 300. |
| 622/1 | When Overlord is monitoring an IDMS service, the IDMS meters PLT_RES and
P_RES can sometimes overflow causing the Overlord monitor to fail with a PE 2.0
at displacements: X4A8A or X4AAE in IIN 2 of module ICL8UCS9MON. This occurs
whether or not the meters PLT_RES or P_RES are referenced in the OSDL. This amendment corrects this problem. |
| 621 | 32/2 program error when monitoring an IDMS service. |
| 619 | New Overlord configuration procedure |
| 617/3 | Overlord monitor fails to alert on hardware that has a state of "UNAV" |
| 616 | Dynamic index dumps at x4948 in UCS0_SCEPTRE if user/library greater than 48 characters. |
| 615 | UCSV dumps if snapshot interval below 1 second |
| 610 | Sceptre Trend Update and Usage Reports which take input data from Sceptre
Trend Files will ignore second and subsequent such files, and will instead treat
the Extract Items which should come from these files as if they came from the
first named Trend File. The same problem occurs with multiple User File input, and also with multiple TPS Monitor File input. In all cases Extract Items which are defined as derived from the second or subsequent User File or TPS Monitor file will be treated as if they came from the first-named file of the appropriate type. (In the case of TPS Monitor Files, this happens only when the Service Name is not supplied in both the Trend Restart data and the Extract Item definition.) The amendment ensures that Sceptre Trend Update and Usage Reports will correctly marry Extract Items with the Trend, User, or TPS Monitor Files from which they are derived. |
| 609/2 | This amendment corrects a problem with Sceptre monitoring a TPMS service
that has more than 255 AVMs, this causes the TPMS monitor and snapshot to abort
with the following error: INTERRUPT ERROR: -700 DESCRIPTION: SIZE ERROR PROGRAM AT BYTE DISPLACEMENT: 2308 (X0904) IN PROCEDURE: UCSCOLTP_C |
| 608/2 | MACROLAN usage may be reported with spurious figures, either greater than
100% or equal to zero, in Sceptre Usage Reports and Trends. This can arise
particularly if SMARTfibre or SMARTarray systems are monitored, but may occur in
other situations as well. This problem may also manifest itself by the
appearance of messages in the Job Journal of the form: FILE ff -VE USAGE yyyy/mm/dd hh:mm:ss ITEM NO: nn where Extract Item 'nn' is derived from Field Name MLAN-BYTES. |
| 601 | Sceptre Usage reports and Trends will produce spurious usage values of zero for SMARTarray controllers if the Extract Item definitions provided for HSDC controllers are used. |
| 600 | When reporting on SMARTarray devices, the FDS screen of Sceptre VME Snapshot will produce figures for Disc Usage which are too large by approximately a factor of three. |
| 599 | The Overlord monitor will fail with a program error type 5 subtype 1 at displacement X21E0 in IIN 1 of module ICL8UCS0SERVICE if an IDMS or TPMS service definition named in the MONITORS division of the OSDL can not be found in the definitions file. |
| 597/1 | UCSOVCONFIGURATION will fail to detect SMARTarray devices on VME systems. |
| 596 | Sceptre Usage Reports which use SMON files for input, and which have a start time of 00:00 may incorporate the last monitor period of the preceding day. This may also occur at times which correspond to the change-over between prime and non-prime schedules. This can occur even with amendment 594 applied. |
| 595 | Sceptre VME Snapshot may not show data for SMARTarray discs on the 'F' screen, although such discs can be monitored on the Overview screen. |
| 594 | Sceptre Usage reports may be produced with an extra report interval that precedes the requested start time, or with a lengthened first interval which embraces the requested start time. |
| 593 | UCS_SETUP or UCS_IMPORT may fail to carry forward certain of the standard Usage Report definitions. |
| 591 | Sceptre Overlord cannot monitor more than one IDMS 400 service from the same service library. |
| 590 | If the first service module loaded by Overlord is an IDMS service, and a
TPMS service module is loaded from the same service library, but is not the
first TPMS service module loaded, Overlord may report error messages of one or
both of the following types: TPMS MESSAGE-TYPE 'XXXXXXXXXXXX' NOT FOUND IN SERVICE 'YYYYYYYY' TPMS AVM-TYPE 'XXXXXXXXXXXX' NOT FOUND IN SERVICE 'YYYYYYYY' |
| 589/4 | Smart Array stats wrong following application of the latest VME envelope. |
| 588 | When a Usage Report or Trend Definition uses 'fuzzy matching' to define one or more of its Extract Items, the figures for such items may sometimes include the total usage (as derived for the similar items with the Occurrence Value *TOTAL) in addition to the true values as derived by fuzzy matching. |
| 587/1 | When a reporting interval is specified, UCS_TPS_FILE_PRINT may show Misaligned time periods within the report Duplicate message names |
| 586/2 | The Overlord OSDL preprocessor may report the following error messages
after loading a TPMS or IDMS service module:
OVERLORD SYS ERR Unable to insert TP details. OVERLORD An error has been reported loading TP service 'xxxxxxxx' OVERLORD SYS ERR Unable to insert IDMS details OVERLORD An error has been reported loading IDMS service 'xxxxxxxx' |
| 585 | This amendment corrects a problem in Sceptre that can cause a record lock to be held indefinitely on the definitions file. This can cause other Sceptre sessions to hang waiting for the lock to be released. |
| 584 | The value shown by Sceptre for the number of Page Lock Table Reserves for an IDMS service is 11 times the correct value. |
| 583 | In a heavily-loaded machine, the Sceptre VME Snapshot may produce figures for channel usage on the 'FDS' screen which exceed 100%. This may also be accompanied by discrepancies between the figures for transfers per second shown on this screen, and the same data shown on the Overview screen. |
| 581 | There is a problem with the Sceptre VME snapshot that can cause it to fail
with a privilege error. This only occurs when a node is lost on a multi-node
machine. This amendment corrects this error. |
| 578/1 | Sceptre produces garbage data when monitoring TPMS 600,610 & 620 services. |
| 577 | If an IDMS service is open, but has not been active when UCS_MONITOR starts, the statistics records for the first snapshot for that service in the UCSTFILE are incomplete. This can have the effect that UCS_FILE_PRINT sometimes shows no statistics for the IDMS service when it becomes active,and/or that UCS_TREND_UPDATE, UCS_TAB and usage reports wrongly show the first active snapshot as having zero values for some statistics items, such as number of success units. |
| 576 | On VME SV293 systems on which RRL3 has been applied, a MAC terminal may in some circumstances appear to hang (in Receive mode) after displaying the Sceptre initial menu screen. |
| 574/1 | Sceptre Usage Reports and Trends may produce incorrect usage figures for duplexed partitions. |
| 573 | Sceptre may produce invalid figures for Disc Controller usage whenproducing Usage Reports or updating Trends, if there are more than 32 controllers attached to a system, and at least 33 of them are being monitored by SMON. |
| 572 | UCS_MONITOR can fail with a bound check failure in procedure UCSCOLTP_C,typically at byte displacement XB30 or XCB8 if a TPMS service is re-prepared with an increased number of terminals or message types, while the UCS_MONITOR is running. |
| 569 | Overlord fails to reset ONETIME and ONCHANGE alerts when requested to do so using a TELL command such as UCSOV_TELL(..., ACTION=START, OBJECT=ALERT_REPORT, ....) even though the TELL command returns a success response. |
| 567 | The Sceptre VME snapshot that can fail with a PE 6/0 in IIN 2 at displacement x0000FA60, if an individual VM has a store size greater than 64 megabytes. |
| 566 | Sceptre Arbiter sometimes produces incorrect values for TPMS service availability times. This can happen if Sceptre treats the records in the accounting journal for the spooler for the job journal as records for the job itself. |
| 563 | The SCL procedure UCS_TPS_FILE_PRINT ignores the INTERVAL parameter when processing the TPS monitoring file. |
| 560/4 | The earlier version of this amendment released with the Software Notice 20 patch files includes an error which may cause Sceptre to fail with a program error in ICL8UCS0TAB when updating a trend or producing a usage report, or may cause Sceptre to produce spurious warning messages related to fuzzy-matched items. |
| 549 | Overlord will fail with a PE 10.2 at displacement X8DF8 in IIN 2 of module ICL8UCS9MON if the allocation to be used for the local alert file has insufficient free space at the start of the Overlord run. Furthermore, Overlord may use an excessive amount of OCP if the allocation used for the local alert file becomes full during an Overlord run. |
| 548/2 | When producing Sceptre Usage Reports, the first interval on the report may be double the requested length of interval. |
| 534 | If only the Overlord option of Sceptre 5.00 is being installed, the installation process will erroneously attempt to set up a Definitions File with an initial size of zero blocks. This is illegal on VME, and will cause the setup process to fail. The attached amendment will remedy this error. |
| 503/1 | Sceptre-Overlord may fail with a PE 32.0 at displacement X39E2 in IIN 2 of module ICL8UCS9MON if a TPMS service module has been loaded using the prepared names added to the module by UCSPREPARESERVICE, and TPMS message- type meters for this service are used in the OSDL. The failure is caused by an error in amendment 503/0 issued with the Sceptre |
| Software Notice 20 | Sceptre Software Notice 20. Sceptre amendment files up to March 1994. |